Condensate Water Flow Meter
Thermax Turbine type meters have been designed to measure condensate return from boiler and hot water lines. We do have some models have maximum temperature ranges to 150ºC. It can measure of demineralized water in utilities, for example in boiler condensate return lines, which requires reliable devices. It provides economical and accurate flow measurement across all industries, with its integrated temperature measurement, proves to be a multivariable flowmeter for considerable additional value in your plant.
Flow Range
Diameter(mm) | Standard Range(m3/h) | Extended Range(m3/h) |
4 | 0.04~0.25 | 0.04~0.4 |
6 | 0.1~0.6 | 0.06~0.6 |
10 | 0.2~1.2 | 0.15~1.5 |
15 | 0.6~6 | 0.4~8 |
20 | 0.8~8 | 0.45~9 |
25 | 1~10 | 0.5~10 |
32 | 1.5~15 | 0.8~15 |
40 | 2~20 | 1~20 |
50 | 4~40 | 2~40 |
65 | 7~70 | 4~70 |
80 | 10~100 | 5~100 |
100 | 20~200 | 10~200 |
125 | 25~250 | 13~250 |
150 | 30~300 | 15~300 |
200 | 80~800 | 40~800 |
Model Selection
Model | LWGY | Description | ||||||||
Diameter | XXX | DN4-DN200 | ||||||||
Converter Type | N1 | 24V DC; Pulse output; No display | ||||||||
N2 | 24V DC; Pulse output;No display; Ex | |||||||||
A | 24V DC; 4-20 mA output; Nodisplay; Ex | |||||||||
E1 | Battery power supply; No output; Ex; Digital Display | |||||||||
E2 | 24V DC; 2-wire 4-20mA output;Ex; Digital Display | |||||||||
E3 | 24V DC; Pulse output; Ex;Display | |||||||||
E4 | 24V DC; 0-20mA output; EX; Digital display | |||||||||
E5 | 24V DC; 3-wire 4-20mA / Pulse output; EX; Digital display | |||||||||
M | 220Vac; 4-20mA output; EX; Digital display | |||||||||
FE | FE:Fluidwell E series converter | |||||||||
FF | FF:Fluidwell F series converter | |||||||||
Notice: | 1)Modbus RS485 is optional for E2,E3,E4,E5 and M type | |||||||||
2)Dual Power(24VDC+Battery) is optional for E2,E3,E4,E5,M | ||||||||||
Accuracy | 10 | ±1.0% of Rate | ||||||||
05 | ±0.5% of Rate | |||||||||
02 | ±0.2% of Rate | |||||||||
Flow Range | S | Standard Range | ||||||||
E | Extended Range | |||||||||
Body Material | S4 | SS304 | ||||||||
S6 | SS316 | |||||||||
PL | Plastic (DN15-DN50) | |||||||||
Rotor Material | Cr | 2Cr13 | ||||||||
CD | CD4MCu | |||||||||
Explosion Proof | BT | Exd II BT6 | ||||||||
NA | No explosion proof | |||||||||
Connection | THM | Male thread; Available from DN4 … DN50 | ||||||||
THF | Female thread; Available from DN4 … DN50 | |||||||||
WAF | Wafer connection | |||||||||
DXX | D16: DIN PN16 flange;D25: DIN PN25… | |||||||||
AXX | A15: ANSI 150# flange;A30: ANSI 300#… | |||||||||
JXX | J10: JIS 10K flange;J20: JIS 20K… | |||||||||
Temperature | T1 | -20…+80 °C | ||||||||
T2 | -20…+120 °C | |||||||||
T3 | -20…+150 °C |